為了給您提供更的電工鋼卷系數(shù)35WW440產(chǎn)品信息,我們上傳了的產(chǎn)品視頻。請(qǐng)花幾分鐘時(shí)間觀看,您會(huì)發(fā)現(xiàn)更多驚喜。
以下是:云南紅河電工鋼卷系數(shù)35WW440的圖文介紹
鹿程國(guó)際貿(mào)易(紅河市分公司)售出的備品備件均提供一年的質(zhì)量保證、并且都經(jīng)過了嚴(yán)格的測(cè)試和認(rèn)證。 公司自成立以來(lái)始終堅(jiān)持以純電子商務(wù)模式運(yùn)營(yíng)、縮減中間環(huán)節(jié)、為客戶在時(shí)間提供優(yōu)質(zhì)的 新能源電工鋼產(chǎn)品及滿意的服務(wù)、為您的生產(chǎn)以及采購(gòu)工作提供‘ 快捷 方便’公司擁有完善的物流供應(yīng)系統(tǒng)、現(xiàn)已與眾多國(guó)外知名品牌生產(chǎn)廠商建立了良好的合作關(guān)系。
電工鋼硅鋼片硅鋼是一種硅鐵合金。用硅鋼軋制的片材是電工領(lǐng)域中應(yīng)用廣的軟磁材料,因而硅鋼片又稱電工鋼片。硅鋼片廣泛用于電動(dòng)機(jī)、發(fā)電機(jī)、變壓器、扼流圈、電磁機(jī)構(gòu)、繼電器及測(cè)量?jī)x表中電機(jī)工業(yè)大量使用厚度為0.35~0.50mm的硅鋼片,用于:中型旋轉(zhuǎn)機(jī),壓縮電機(jī),通用馬達(dá),小型精密電機(jī),電動(dòng)汽車,壓縮機(jī),通用電機(jī),電源變壓器,精密變壓器,節(jié)能電機(jī),焊機(jī)變壓器,穩(wěn)壓器,磁性密封器,加速器用電磁鐵,汽車電機(jī)等;在電信高頻技術(shù)中常用0.05~0.20mm的薄帶鋼片,以便更有效地降低渦流損耗。熱軋硅鋼片厚度為0.35~0.50mm,密度為7.55~7.70g/cm3,多用于大、中、小型交、直流電動(dòng)機(jī);冷軋無(wú)取向硅鋼片厚度為0.35~0.50mm,密度為7.65~7.75g/cm3,多用于大型交流發(fā)電機(jī)、電動(dòng)機(jī),大、中、小型交、直流電動(dòng)機(jī);冷軋取向硅鋼片厚度為0.23mm 0.27mm 0.3mm 0.35mm,密度為7.65g/cm3,多用于電力變壓器、油浸式變壓器,干式變壓器,電抗器、磁放大器等;冷軋取向薄帶厚度為0.05~0.20mm,多用于無(wú)線電高頻變壓器。
電工鋼硅鋼片硅鋼是一種硅鐵合金。用硅鋼軋制的片材是電工領(lǐng)域中應(yīng)用廣的軟磁材料,因而硅鋼片又稱電工鋼片。硅鋼片廣泛用于電動(dòng)機(jī)、發(fā)電機(jī)、變壓器、扼流圈、電磁機(jī)構(gòu)、繼電器及測(cè)量?jī)x表中電機(jī)工業(yè)大量使用厚度為0.35~0.50mm的硅鋼片,用于:中型旋轉(zhuǎn)機(jī),壓縮電機(jī),通用馬達(dá),小型精密電機(jī),電動(dòng)汽車,壓縮機(jī),通用電機(jī),電源變壓器,精密變壓器,節(jié)能電機(jī),焊機(jī)變壓器,穩(wěn)壓器,磁性密封器,加速器用電磁鐵,汽車電機(jī)等;在電信高頻技術(shù)中常用0.05~0.20mm的薄帶鋼片,以便更有效地降低渦流損耗。熱軋硅鋼片厚度為0.35~0.50mm,密度為7.55~7.70g/cm3,多用于大、中、小型交、直流電動(dòng)機(jī);冷軋無(wú)取向硅鋼片厚度為0.35~0.50mm,密度為7.65~7.75g/cm3,多用于大型交流發(fā)電機(jī)、電動(dòng)機(jī),大、中、小型交、直流電動(dòng)機(jī);冷軋取向硅鋼片厚度為0.23mm 0.27mm 0.3mm 0.35mm,密度為7.65g/cm3,多用于電力變壓器、油浸式變壓器,干式變壓器,電抗器、磁放大器等;冷軋取向薄帶厚度為0.05~0.20mm,多用于無(wú)線電高頻變壓器。
電工鋼硅鋼片Electrical steel, also known as silicon steel sheet, is an indispensable metal material in the power, electronics, and military industries, and is also the largest functional material in production. It is mainly used as the iron core for various motors, generators, and transformers. Since it is a functional material, its performance testing also revolves around "function". These indicators are often mentioned in trade and processing processes, and a brief understanding can help everyone better carry out their work. The performance testing of electrical steel mainly includes the following aspects: magnetic inspection, stacking coefficient inspection, coating adhesion inspection, repeated bending inspection, size and shape surface inspection, and conventional mechanical property inspection. In addition to the types of products listed above, there are also some special purpose electrical steel plates, such as 0.15 and 0.20mm thick 3% Si cold-rolled non oriented silicon steel strips and 0.025, 0.05, and 0.1mm thick 3% Si cold-rolled oriented silicon steel strips, which are used as intermediate and intermediate grade High frequency motors and transformers, as well as pulse transformers, etc; 0.7mm thick 3% Si high-strength cold-rolled non oriented silicon steel plate for relays and power switches; High strength cold-rolled electrical steel plate for new high-speed motor rotors; Low carbon electrical steel hot-rolled thick and cold-rolled plates for magnetic shielding and high-energy accelerator electromagnets such as medical magnetic resonance tomography scanners; 4.5% to 6.5% Si high silicon steel plates for high-frequency motors, transformers, and magnetic shielding.
Generally, motors, transformers, and other electrical components are required to have high efficiency, low power consumption, small size, and light weight. Electrical steel plates are usually guaranteed to have magnetic properties based on core loss and magnetic induction strength. Magnetic induction strength is the number of magnetic lines passing through a unit cross-sectional area of the iron core, also known as magnetic flux density. It represents the material‘s magnetization ability, measured in T. The magnetic induction strength of electrical steel plates is high, and the excitation current (also known as no-load current) of the iron core is reduced. Copper and iron losses are also reduced, which can save electrical energy. When the power of the motor and transformer remains constant, the magnetic induction intensity is high, and the design Bm can be increased. The cross-sectional area of the iron core can be reduced, which reduces the volume and weight of the iron core, and saves the amount of electrical steel plates, wires, insulation materials, and structural materials used. This can reduce the total loss and manufacturing cost of the motor and transformer, and is beneficial for the manufacturing, installation, and transportation of large transformers and motors. The main requirements for the performance of silicon steel are:
1. Low iron loss is the most important indicator of the quality of silicon steel sheets. Various countries classify grades based on iron loss values, with the lower the iron loss, the higher the grade.
2. Under strong magnetic fields, the magnetic induction intensity (magnetic induction) is high, which reduces the volume and weight of the iron core of the motor and transformer, saving silicon steel sheets, copper wires, and insulation materials.
3. The surface is smooth, flat, and the thickness is uniform, which can improve the filling coefficient of the iron core.
4. Good lamination performance is more important for manufacturing micro and small electric motors.
5. The adhesion and weldability of the surface insulation film are good, which can prevent corrosion and improve the punching performan
點(diǎn)擊查看鹿程國(guó)際貿(mào)易(紅河市分公司)的【產(chǎn)品相冊(cè)庫(kù)】以及我們的【產(chǎn)品視頻庫(kù)】